Parameter ID 68
Parameter
Name
High Speed Serial Data LSB Position
Data High Speed Serial Data LSB Position (Unit: bit) Range = 0 ~ 4
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
The least significant bit position of the target position data of high-speed serial
communication 20 bit data can be specified.
Range = 0 bit ~ 4 bit
(For details, see 2.8.3. , “High-speed serial communication”)